technical data
 

Technical data of the EMT pick-up's


(guaranteed data T-series)
  TSD15 sph
XSD15 sph
TSD15 SFL
XSD15 SFL
TSD15SFL
TSD15sph
LZi
TMD25 TND65
Order number 9 935 033
9 935 034
9 935 000
9 935 008
9 935 170
9 935 171
9 935 001 9 935 002
Repair number R 935 033
R 935 034
R 935 000
R 935 008
R 935 170
R 935 171
R 935 001 R 935 002
Stylus diameter (µ) 15 6 6
15
25 Micro groove 65 Standard groove
Diamond/Sapphire Diamond Diamond Diamond Diamond Diamond
Needleholder exchangeable no no no no no
Tracking force 2-3p 2-3p 2-3p 2-3p 2-3p
mono/stereo stereo stereo stereo mono (red/green) mono (red/green)
Impedance 2x24 Ohms 2x24 Ohms 2x6 Ohms 24 Ohms right 24 Ohms right
Transducing factor (mV*s/cm) 2x0,21 2x0,21 2x0,05 0,21 0,21
Frequency range (Hz) 20...30.000 20...30.000 20...20.000 20...20.000 20...30.000
Frequency response 40Hz-12,5kHz ±2dB ±2dB ±2dB ±2dB ±2dB
Level difference between 40Hz and 12,5kHz max. 1dB max. 1dB max. 1dB - -
Crosstalk min. 25dB min. 25dB min. 25dB - -
FIM max. 0,5% max. 0,5% max. 0,5% max. 1% max. 1%
Vertical tracking angle 15° ±3°
23° ±3°
15° ±3°
23° ±3°
23° ±3° 15° ±3°
23° ±3°
15° ±3°
23° ±3°
Compliance 15µm/mN 15µm/mN 15µm/mN 15µm/mN 15µm/mN
Eff. mass at the needle tip approx. 1mg approx. 1mg approx. 1mg approx. 1mg approx. 1mg
Tone arm connection TSD: EMT arm
XSD: SME
TSD: EMT arm
XSD: SME
SME / EMT on request EMT arm EMT arm
Weight (g) 17,5 (XSD: 21) 17,5 (XSD: 21) 30 17,5 17,5
Recommended tone arm mass          

(guaranteed data H- and J-series)
  HSD6 JSD5 JSD6
Order number 9 936 000 9 937 000 9 937 001
Repair number R 936 000 R 937 000 R 937 001
Stylus diameter (µ) 6 5 6
Diamond/Sapphire Diamond Diamond Diamond
Needleholder exchangeable no no no
Tracking force 2-3p 2.2-2.5p 2.2-2.5p
mono/stereo stereo stereo stereo
Impedance 2x24 Ohms 2x20 Ohms 2x20 Ohms
Transducing factor (mV*s/cm) 2x0,21 2x0,21 2x0,21
Frequency range (Hz) 20...20.000 20...30.000 20...30.000
Frequency response 40Hz-12,5kHz ±2dB ±2dB ±2dB
Level difference between 40Hz and 12,5kHz max. 1dB max. 1dB max. 1dB
Crosstalk min. 25dB min. 26dB min. 26dB
FIM max. 0,5% max. 0,5% max. 0,5%
Vertical tracking angle 23° ±3° 23° ±3° 23° ±3°
Compliance 15µm/mN 15µm/mN 15µm/mN
Eff. mass at the needle tip approx. 1mg approx. 1mg approx. 1mg
Tone arm connection 1/2" with pins 1/2" with gold plated pins 1/2" with gold plated pins
Weight (g) approx. 12 approx. 11 approx. 11
Recommended tone arm mass 10-20g 15-35g 15-35g

Technical data of EMT pick-up's (O-series)

OFS25 OFD25 OFS65 OFD65
Order number 9 935 225 9 935 325 9 935 265 9 935 365
Repair number R 935 225 R 935 325 R 935 265 R 935 365
Stylus diameter (µ) 25 Micro groove 25 Micro groove 65 Standard groove 65 Standard groove
Diamond/Sapphire Sapphire Diamond Sapphire Diamond
Needleholder exchangeable yes no yes no
Order number needleholder (10) 9 935 927 - 9 935 927 -
Tracking force 5p 5p 9p (4p heavier than OFS25) 9p (4p heavier than OFD25)
mono/stereo mono (red/green) mono (red/green) mono (red/green) mono (red/green)
Impedance 37 Ohms right 37 Ohms right 25 Ohms right 25 Ohms right
Transducing factor (mV*s/cm) 1,15 1,15 0,85 0,85
Frequency range (Hz) 30...15.000 30...15.000 30...15.000 30...15.000
Frequency response 40Hz-12,5kHz ±2dB ±2dB ±2dB ±2dB
Level difference between 40Hz and 12,5kHz - - - -
Crosstalk - - - -
FIM max. 1% max. 1% max. 1% max. 1%
Vertical tracking angle 90° 90° 90° 90°
Compliance 5µm/mN 5µm/mN 5µm/mN 5µm/mN
Eff. mass at the needle tip max. 2mg max. 2mg max. 2mg max. 2mg
Tone arm connection EMT arm EMT arm EMT arm EMT arm
weight (g) 33 33 37 37
Recommended tone arm mass        
© fabritius 2004 -13